@ -196,10 +196,6 @@ Alan's mail): |
|
|
|
|
|
|
|
* Output File Format Changes - |
|
|
|
|
|
|
|
Rawfile format changed to PSPICE Probe format (Usable with Demo |
|
|
|
version of Microsim's Probe). (NOTE: Do not rely on this, we may |
|
|
|
revert to the old format in the next release). |
|
|
|
|
|
|
|
Text mode .OP results even though "rawfile" written. |
|
|
|
|
|
|
|
Internal device nodes are not saved to "rawfile" (reduces file |
|
|
|
@ -270,13 +266,12 @@ region, which means that when this jump allows the drain current to be |
|
|
|
calculated, Vdsat can already be well above zero. This leads to a |
|
|
|
discontinuity of drain current with respect to gate voltage. The code |
|
|
|
is now modified to use Vbin for the jump decision. It looks like the |
|
|
|
code should actually use Vth as the threshold voltage, but since |
|
|
|
PSPICE and HSPICE both follow the original Berkeley code, this was |
|
|
|
left alone. |
|
|
|
code should actually use Vth as the threshold voltage, but since other |
|
|
|
SPICE simulators follow the original Berkeley code, this was left alone. |
|
|
|
|
|
|
|
* New Model Parameters - |
|
|
|
|
|
|
|
A PSPICE/HSPICE-like "M" device parameter (i.e. M devices in parallel) |
|
|
|
A device multiplier instance parameter "M" (i.e. M devices in parallel) |
|
|
|
was added to the MOS1,2,3 and BSIM3 mosfet models. |
|
|
|
|
|
|
|
* Input Read-in and Checking - |
|
|
|
@ -10997,8 +10992,8 @@ region, which means that when this jump allows the drain current to be |
|
|
|
calculated, Vdsat can already be well above zero. This leads to a |
|
|
|
discontinuity of drain current with respect to gate voltage. The code |
|
|
|
is now modified to use Vbin for the jump decision. It looks like the |
|
|
|
code should actually use Vth as the threshold voltage, but since |
|
|
|
PSPICE and HSPICE both follow the original Berkeley code, this was |
|
|
|
code should actually use Vth as the threshold voltage, but since other |
|
|
|
SPICE simulators follow the original Berkeley code, this was |
|
|
|
left alone. The affected code can be found in @code{MOS2load()}: |
|
|
|
|
|
|
|
@example |
|
|
|
|